Skip to content Skip to footer

Insulation Jacket

Core Function & Energy Efficiency:

  • Designed to insulate a wide variety of equipment including valves, flanges, pumps, heat exchangers, elbow bends, etc.
  • Helps deliver up to 97% energy conservation and provides exceptional thermal conductivity properties.
  • Also used to provide insulation against low temperatures and protect personnel from burns by reducing the temperature of exposed pipework surfaces.

Financial Benefits & ROI:

  • End users enjoy an attractive return on their insulation system investment based solely on energy savings.
  • The payback period accelerates as equipment size and operating temperature increase.

    ENQUIRE NOW

    SKU: 01 Category: Product ID: 27281

    Technical Specification

    Insulation System – Energy Savings

     

    TEMP Valve Size (inches)
    °F °C 2″ 3″ 4″ 6″ 8″ 10″ 12″ 14″
    250 121 777.4 1207.95 1639.45 2580.64 3811</td > 5101.8 5881.05 8565.49
    350 176 1532 2361.5 3307.21 5031.87 7424.68 9940.09 11473 16659
    450 232 2602.82 4027.54 5636.23 8562.23 12623.87 16969.42 19634.45 28285.95
    550 287 3991.34 6167.23 8625.34 13088.87 19286.7 25967.32 30085.65 43169.45
    650 343 580.82 9004.49 12546.96 18990.16 27977.35 37500.45 43589.6 62199.25
    750 398 7985.69 12364.98 17226.12 26060.77 38381.95 51445.35 59811.5 85309.55
    850 454 10805.67 16691.34 23257.81 36259.36 51685.85 69221.7 80651 114830

     

     

    Btu / Hour Saved with Valve Insulation System

     

    Monthly Energy Savings

     

     

    Insulation System – Product Payback Analysis

     

    TEMP Valve Size (inches)
    °F °C 2″ 3″ 4″ 6″ 8″ 10″ 12″ 14″
    250 121 20.93 18.78 17.72 16.12 15.25 15.35 16.67 13.6
    350 176 1068 9.61 9.07 8.27 7.83 7.88 8.54 6.99
    450 232 7.24 6.38 5.93 5.28 4.93 4.74 5.21 4.24
    550 287 5.63 4.65 4.27 3.74 3.44 3.18 3.54 2.86
    650 343 4.42 3.47 3.28 2.84 2.52 2.5 2.71 2.28
    750 398 3.22 2.53 2.39 2.07 1.84 1.82 1.98 1.66
    850 454 2.65 2.05 1.9 1.65 1.45 1.42 1.53 1.28

     

     

    Energy Saved / Year with Valve Insulation System

     

    Payback Period (Months)

    Key Benefits

    Primary Metrics:

    • 45% reduction in energy costs.
    • 25% reduction in heater watt density.
    • 40% faster start-up time.

    Design & Practicality:

    • Removable / Reusable
    • Tool-Free installation
    • Rapid payback period
    • Exceptional service life

    Technology & Quality:

    • Optimal Thermal Efficiency
    • Precise Form-Fit Design
    • CAD CAM Technology
    • Standard / Specification Conformance

    Typical Applications

    • Exchangers
    • Exhaust Manifolds
    • Flanges
    • Filters
    • Instruments
    • Piping
    • Pumps
    • Turbines
    • Valves

    Typical Requirements

    • Energy Conservation
    • Personnel Protection
    • Process Stability
    • Leak Detection
    • Freeze Protection
    • Fire Protection
    • Acoustical Abatement
    • Corrosion Protection
    • Simplified Maintenanc
    Quick Enquiry
    close slider